smilint output for ./PARALLEL-MIB
Message Severities |
Severity | Count |
minor error | 1 |
warning | 6 |
Message Types |
Type | Count |
import-unused (warning) | 1 |
index-element-accessible (warning) | 5 |
revision-missing (minor error) | 1 |
Messages:
PARALLEL-MIB
1: -- extracted from rfc1660.txt
2: -- at Mon Nov 15 17:11:52 1999
3:
4: PARALLEL-MIB DEFINITIONS ::= BEGIN
5:
6: IMPORTS
7: MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE,
7: warning -
warning: identifier `NOTIFICATION-TYPE' imported from module `SNMPv2-SMI' is never used
8: Counter32, Integer32
9: FROM SNMPv2-SMI
10: InterfaceIndex
11: FROM IF-MIB
12: transmission
13: FROM RFC1213-MIB
14: MODULE-COMPLIANCE, OBJECT-GROUP
15: FROM SNMPv2-CONF;
16:
17:
18: para MODULE-IDENTITY
19: LAST-UPDATED "9405261700Z"
20: ORGANIZATION "IETF Character MIB Working Group"
21: CONTACT-INFO
22: " Bob Stewart
23: Postal: Xyplex, Inc.
24: 295 Foster Street
25: Littleton, MA 01460
26:
27: Tel: 508-952-4816
28: Fax: 508-952-4887
29: E-mail: rlstewart@eng.xyplex.com"
30:
31: DESCRIPTION
32: "The MIB module for Parallel-printer-like hardware devices."
33: ::= { transmission 34 }
33: minor error -
revision for last update is missing
34:
35:
36: -- Generic Parallel-printer-like information
...
58:
59: paraPortEntry OBJECT-TYPE
59: warning -
warning: index element `paraPortIndex' of row `paraPortEntry' should be not-accessible in SMIv2 MIB
60: SYNTAX ParaPortEntry
61: MAX-ACCESS not-accessible
62: STATUS current
63: DESCRIPTION
64: "Status and parameter values for a port."
65: INDEX { paraPortIndex }
66: ::= { paraPortTable 1 }
67:
68: ParaPortEntry ::=
69: SEQUENCE {
70: paraPortIndex
71: InterfaceIndex,
72: paraPortType
73: INTEGER,
74: paraPortInSigNumber
75: Integer32,
76: paraPortOutSigNumber
77: Integer32
78: }
...
135:
136: paraInSigEntry OBJECT-TYPE
136: warning -
warning: index element `paraInSigPortIndex' of row `paraInSigEntry' should be not-accessible in SMIv2 MIB
136: warning -
warning: index element `paraInSigName' of row `paraInSigEntry' should be not-accessible in SMIv2 MIB
137: SYNTAX ParaInSigEntry
138: MAX-ACCESS not-accessible
139: STATUS current
140: DESCRIPTION
141: "Input control signal status for a hardware port."
142: INDEX { paraInSigPortIndex, paraInSigName }
143: ::= { paraInSigTable 1 }
144:
145: ParaInSigEntry ::=
146: SEQUENCE {
147: paraInSigPortIndex
148: InterfaceIndex,
149: paraInSigName
150: INTEGER,
151: paraInSigState
152: INTEGER,
153: paraInSigChanges
154: Counter32
155: }
...
202:
203: paraOutSigEntry OBJECT-TYPE
203: warning -
warning: index element `paraOutSigPortIndex' of row `paraOutSigEntry' should be not-accessible in SMIv2 MIB
203: warning -
warning: index element `paraOutSigName' of row `paraOutSigEntry' should be not-accessible in SMIv2 MIB
204: SYNTAX ParaOutSigEntry
205: MAX-ACCESS not-accessible
206: STATUS current
207: DESCRIPTION
208: "Output control signal status for a hardware port."
209: INDEX { paraOutSigPortIndex, paraOutSigName }
210: ::= { paraOutSigTable 1 }
211:
212: ParaOutSigEntry ::=
213: SEQUENCE {
214: paraOutSigPortIndex
215: InterfaceIndex,
216: paraOutSigName
217: INTEGER,
218: paraOutSigState
219: INTEGER,
220: paraOutSigChanges
221: Counter32
222: }