smilint output for ./ITU-IANA-ALARM-TC
Message Severities |
Severity | Count |
error | 3 |
warning | 3 |
Message Types |
Type | Count |
macro-not-imported (error) | 2 |
module-identity-missing (error) | 1 |
module-name-suffix (warning) | 1 |
type-unref (warning) | 2 |
Messages:
ITU-IANA-ALARM-TC
1: -- extracted from draft-ietf-disman-alarm-mib-04.txt
2: -- at Wed Jan 9 06:07:57 2002
3:
4: ITU-IANA-ALARM-TC DEFINITIONS ::= BEGIN
5:
6: IANAItuProbableCause ::= TEXTUAL-CONVENTION
6: error -
macro `TEXTUAL-CONVENTION' has not been imported from module `SNMPv2-TC'
6: warning -
warning: current type `IANAItuProbableCause' is not referenced in this module
7: STATUS current
8: DESCRIPTION
9: "ITU probable cause values for the alarms as per M.3100,
10: X.733 and X.736."
11: SYNTAX INTEGER
12: {
13: aIS (1),
14: callSetUpFailure (2),
15: degradedSignal (3),
16: farEndReceiverFailure (4),
17: framingError (5),
18: lossOfFrame (6),
19: lossOfPointer (7),
20: lossOfSignal (8),
21: payloadTypeMismatch (9),
22: transmissionError (10),
23: remoteAlarmInterface (11),
24: excessiveBER (12),
25: pathTraceMismatch (13),
26: unavailable (14),
27: signalLabelMismatch (15),
28: lossOfMultiFrame (16),
29: receiveFailure (17),
30: transmitFailure (18),
31: modulationFailure (19),
32: demodulationFailure (20),
33: broadcastChannelFailure (21),
34: connectionEstablishmentError (22),
35: invalidMessageReceived (23),
36: localNodeTransmissionError (24),
37: remoteNodeTransmissionError (25),
38: routingFailure (26),
39:
40: --Values 27-50 are reserved for communications alarm related
41: --probable causes
42: -- The following are used with equipment alarm.
43:
44: backplaneFailure (51),
45: dataSetProblem (52),
46: equipmentIdentifierDuplication (53),
47: externalIFDeviceProblem (54),
48: lineCardProblem (55),
49: multiplexerProblem (56),
50: nEIdentifierDuplication (57),
51: powerProblem (58),
52: processorProblem (59),
53: protectionPathFailure (60),
54: receiverFailure (61),
55: replaceableUnitMissing (62),
56: replaceableUnitTypeMismatch (63),
57: synchronizationSourceMismatch (64),
58: terminalProblem (65),
59: timingProblem (66),
60: transmitterFailure (67),
61: trunkCardProblem (68),
62: replaceableUnitProblem (69),
63: realTimeClockFailure (70),
64: --An equipment alarm to be issued if the system detects that the
65: --real time clock has failed
66: antennaFailure (71),
67: batteryChargingFailure (72),
68: diskFailure (73),
69: frequencyHoppingFailure (74),
70: iODeviceError (75),
71: lossOfSynchronisation (76),
72: lossOfRedundancy (77),
73: powerSupplyFailure (78),
74: signalQualityEvaluationFailure (79),
75: tranceiverFailure (80),
76: protectionMechanismFailure (81),
77: protectingResourceFailure (82),
78: -- Values 83-100 are reserved for equipment alarm related probable
79: -- causes
80: -- The following are used with environmental alarm.
81: airCompressorFailure (101),
82: airConditioningFailure (102),
83: airDryerFailure (103),
84: batteryDischarging (104),
85: batteryFailure (105),
86: commercialPowerFailure (106),
87: coolingFanFailure (107),
88: engineFailure (108),
89: fireDetectorFailure (109),
90: fuseFailure (110),
91: generatorFailure (111),
92: lowBatteryThreshold (112),
93: pumpFailure (113),
94: rectifierFailure (114),
95: rectifierHighVoltage (115),
96: rectifierLowFVoltage (116),
97: ventilationsSystemFailure (117),
98: enclosureDoorOpen (118),
99: explosiveGas (119),
100: fire (120),
101: flood (121),
102: highHumidity (122),
103: highTemperature (123),
104: highWind (124),
105: iceBuildUp (125),
106: intrusionDetection (126),
107: lowFuel (127),
108: lowHumidity (128),
109: lowCablePressure (129),
110: lowTemperatue (130),
111: lowWater (131),
112: smoke (132),
113: toxicGas (133),
114: coolingSystemFailure (134),
115: externalEquipmentFailure (135),
116: externalPointFailure (136),
117: -- Values 137-150 are reserved for environmental alarm related
118: -- probable causes
119: -- The following are used with Processing error alarm.
120: storageCapacityProblem (151),
121: memoryMismatch (152),
122: corruptData (153),
123: outOfCPUCycles (154),
124: sfwrEnvironmentProblem (155),
125: sfwrDownloadFailure (156),
126: lossOfRealTimel (157),
127: --A processing error alarm to be issued after the system has
128: --reinitialised. This will indicate
129: --to the management systems that the view they have of the managed
130: --system may no longer
131: --be valid. Usage example: The managed
132: --system issues this alarm after a reinitialization with severity
133: --warning to inform the
134: --management system about the event. No clearing notification will
135: --be sent.
136: applicationSubsystemFailure (159),
137: configurationOrCustomisationError (160),
138: databaseInconsistency (161),
139: fileError (162),
140: outOfMemory (163),
141: softwareError (164),
142: timeoutExpired (165),
143: underlayingResourceUnavailable (166),
144: versionMismatch (167),
145:
146: --Values 168-200 are reserved for processing error alarm related
147: -- probable causes.
148: bandwidthReduced (201),
149: congestion (202),
150: excessiveErrorRate (203),
151: excessiveResponseTime (204),
152: excessiveRetransmissionRate (205),
153: reducedLoggingCapability (206),
154: systemResourcesOverload (207 ),
155:
156: other (255),
157: adapterError (256),
158: callEstablishmentError (257),
159: communicationsProtocolError (258),
160: communicationsSubsystemFailure (259),
161: configurationOrCustomizationError (260),
162: cpuCyclesLimitExceeded (261),
163: dataSetOrModemError (262),
164: dteDceInterfaceError (263),
165: equipmentMalfunction (264),
166: excessiveVibration (265),
167: fireDetected (266),
168: floodDetected (267),
169: heatingVentCoolingSystemProblem (268),
170: humidityUnacceptable (269),
171: inputOutputDeviceError (270),
172: inputDeviceError (271),
173: lanError (272),
174: leakDetected (273),
175: materialSupplyExhausted (274),
176: ouputDeviceError (275),
177: performanceDegraded (276),
178: pressureUnacceptable (277),
179: queueSizeExceeded (278),
180: resourceAtOrNearingCapacity (279),
181: responseTimeExecessive (280),
182: retransmissionRateExcessive (281),
183: softwareProgramAbnormallyTerminated (282),
184: softwareProgramError (283),
185: temperatureUnacceptable (284),
186: thresholdCrossed (285),
187: toxicLeakDetected (286),
188: underlyingResourceUnavailable (287),
189: authenticationFailure (288),
190: breachOfConfidentiality (289),
191: cableTamper (290),
192: delayedInformation (291),
193: denialOfService (292),
194: duplicateInformation (293),
195: informationMissing (294),
196: informationModificationDetected (295),
197: informationOutOfSequence (296),
198: keyExpired (297),
199: nonRepudiationFailure (298),
200: outOfHoursActivity (299),
201: outOfService (300),
202: proceduralError (301),
203: unauthorizedAccessAttempt (302),
204: unexpectedInformation (303)
205: }
206:
207: IANAItuEventType ::= TEXTUAL-CONVENTION
207: error -
macro `TEXTUAL-CONVENTION' has not been imported from module `SNMPv2-TC'
207: warning -
warning: current type `IANAItuEventType' is not referenced in this module
208: STATUS current
209: DESCRIPTION
210: "The ITU event Type values as per M.3100"
211: SYNTAX INTEGER
212: {
213: other (1),
214: communicationsAlarm (2),
215: qualityOfServiceAlarm (3),
216: processingErrorAlarm (4),
217: equipmentAlarm (5),
218: environmentalAlarm (6),
219: integrityViolation (7),
220: operationalViolation (8),
221: physicalViolation (9),
222: securityServiceOrMechanismViolation (10),
223: timeDomainViolation (11)
224: }
225:
226: END
226: warning -
warning: module name `ITU-IANA-ALARM-TC' should match `*-MIB'
226: error -
missing MODULE-IDENTITY clause in SMIv2 MIB
227:
228: --
229: -- Copyright (C) The Internet Society (2001). All Rights Reserved.
230: --
231: -- This document and translations of it may be copied and furnished to
232: -- others, and derivative works that comment on or otherwise explain it
233: -- or assist in its implementation may be prepared, copied, published
234: -- and distributed, in whole or in part, without restriction of any kind,
235: -- provided that the above copyright notice and this paragraph are
236: -- included on all such copies and derivative works. However, this
237: -- document itself may not be modified in any way, such as by removing
238: -- the copyright notice or references to the Internet Society or other
239: -- Internet organizations, except as needed for the purpose of
240: -- developing Internet standards in which case the procedures for
241: -- copyrights defined in the Internet Standards process must be followed,
242: -- or as required to translate it into languages other than English.
243: --
244: -- The limited permissions granted above are perpetual and will not be
245: -- revoked by the Internet Society or its successors or assigns.
246: --
247: -- This document and the information contained herein is provided on an
248: -- "AS IS" basis and THE INTERNET SOCIETY AND THE INTERNET ENGINEERING
249: -- TASK FORCE DISCLAIMS ALL WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT
250: -- NOT LIMITED TO ANY WARRANTY THAT THE USE OF THE INFORMATION HEREIN
251: -- WILL NOT INFRINGE ANY RIGHTS OR ANY IMPLIED WARRANTIES OF
252: -- MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
253: