smilint output for ./FRNETSERV-MIB


Message Severities
SeverityCount
minor error5
warning20
Message Types
TypeCount
group-unref (warning)1
integer-misuse (warning)18
notification-not-reversible (warning)1
notification-object-access (minor error)5

Messages:

FRNETSERV-MIB

   1: -- extracted from rfc2954.txt
   2: -- at Tue Oct 17 07:11:19 2000
 436: 
 437:         frMgtVCSigUserN391 OBJECT-TYPE
 438:             SYNTAX      INTEGER (1..255)
 438: warning - warning: use Integer32 instead of INTEGER in SMIv2
 439:             UNITS       "Polls"
 440:             MAX-ACCESS  read-only
 441:             STATUS      current
 442:             DESCRIPTION
 443:                     "The value of this object identifies the User-side
 444:                     N391 full status polling cycle value for this
 445:                     UNI/NNI logical port.  If the logical port is not
 446:                     performing user-side (bidirectional) procedures,
 447:                     then this object is not instantiated and an
 448:                     attempt to read will result in the noSuchInstance
 449:                     exception response."
 450:             REFERENCE   "Q.933 Annex A [22],
 451:                          T1.617 Annex D [17]"
 452:             DEFVAL { 6 }
 453:             ::= { frMgtVCSigEntry 2 }
 454: 
 455:         frMgtVCSigUserN392 OBJECT-TYPE
 456:             SYNTAX      INTEGER (1..10)
 456: warning - warning: use Integer32 instead of INTEGER in SMIv2
 457:             UNITS       "Events"
 458:             MAX-ACCESS  read-only
 459:             STATUS      current
 460:             DESCRIPTION
 461:                     "The value of this object identifies the User-side
 462:                     N392 error threshold value for this UNI/NNI
 463:                     logical port.  If the logical port is not
 464:                     performing user-side (bidirectional) procedures,
 465:                     then this object is not instantiated."
 466:             REFERENCE   "Q.933 Annex A [22],
 467:                          T1.617 Annex D [17]"
 468:             DEFVAL { 3 }
 469:             ::= { frMgtVCSigEntry 3 }
 470: 
 471:         frMgtVCSigUserN393 OBJECT-TYPE
 472:             SYNTAX      INTEGER (1..10)
 472: warning - warning: use Integer32 instead of INTEGER in SMIv2
 473:             UNITS       "Events"
 474:             MAX-ACCESS  read-only
 475:             STATUS      current
 476:             DESCRIPTION
 477:                     "The value of this object identifies the User-side
 478:                     N393 monitored events count value for this UNI/NNI
 479:                     logical port.  If the logical port is not
 480:                     performing user-side (bidirectional) procedures,
 481:                     then this object is not instantiated."
 482:             REFERENCE   "Q.933 Annex A [22],
 483:                          T1.617 Annex D [17]"
 484:             DEFVAL { 4 }
 485:             ::= { frMgtVCSigEntry 4 }
 486: 
 487:         frMgtVCSigUserT391 OBJECT-TYPE
 488:             SYNTAX      INTEGER (5..30)
 488: warning - warning: use Integer32 instead of INTEGER in SMIv2
 489:             UNITS       "Seconds"
 490:             MAX-ACCESS  read-only
 491:             STATUS      current
 492:             DESCRIPTION
 493:                     "The value of this object identifies the User-side
 494:                     T391 link integrity verification polling timer
 495:                     value for this UNI/NNI logical port.  If the
 496:                     logical port is not performing user-side
 497:                     procedures, then this object is not instantiated."
 498:             REFERENCE   "Q.933 Annex A [22],
 499:                          T1.617 Annex D [17]"
 500:             DEFVAL { 10 }
 501:             ::= { frMgtVCSigEntry 5 }
 502: 
 503:         frMgtVCSigNetN392 OBJECT-TYPE
 504:             SYNTAX      INTEGER (1..10)
 504: warning - warning: use Integer32 instead of INTEGER in SMIv2
 505:             UNITS       "Events"
 506:             MAX-ACCESS  read-only
 507:             STATUS      current
 508:             DESCRIPTION
 509:                     "The value of this object identifies the Network-
 510:                     side N392 error threshold value (nN2 for LMI) for
 511:                     this UNI/NNI logical port.  If the logical port is
 512:                     not performing network-side procedures, then this
 513:                     object is not instantiated."
 514:             REFERENCE   "Q.933 Annex A [22],
 515:                          T1.617 Annex D [17],
 516:                          LMI [24]"
 517:             DEFVAL { 3 }
 518:             ::= { frMgtVCSigEntry 6 }
 519: 
 520:         frMgtVCSigNetN393 OBJECT-TYPE
 521:             SYNTAX      INTEGER (1..10)
 521: warning - warning: use Integer32 instead of INTEGER in SMIv2
 522:             UNITS       "Events"
 523:             MAX-ACCESS  read-only
 524:             STATUS      current
 525:             DESCRIPTION
 526:                     "The value of this object identifies the Network-
 527:                     side N393 monitored events count value (nN3 for
 528:                     LMI) for this UNI/NNI logical port.  If the
 529:                     logical port is not performing network-side
 530:                     procedures, then this object is not instantiated."
 531:             REFERENCE   "Q.933 Annex A [22],
 532:                          T1.617 Annex D [17],
 533:                          LMI [24]"
 534:             DEFVAL { 4 }
 535:             ::= { frMgtVCSigEntry 7 }
 536: 
 537:         frMgtVCSigNetT392 OBJECT-TYPE
 538:             SYNTAX      INTEGER (5..30)
 538: warning - warning: use Integer32 instead of INTEGER in SMIv2
 539:             UNITS       "Seconds"
 540:             MAX-ACCESS  read-only
 541:             STATUS      current
 542:             DESCRIPTION
 543:                     "The value of this object identifies the Network-
 544:                     side T392 polling verification timer value (nT2
 545:                     for LMI)  for this UNI/NNI logical port.  If the
 546:                     logical port is not performing network-side
 547:                     procedures, then this object is not instantiated."
 548:             REFERENCE   "Q.933 Annex A [22],
 549:                          T1.617 Annex D [17],
 550:                          LMI [24]"
 551:             DEFVAL { 15 }
 552:             ::= { frMgtVCSigEntry 8 }
 553: 
 554:         frMgtVCSigNetnN4 OBJECT-TYPE
 555:             SYNTAX      INTEGER (5..5)
 555: warning - warning: use Integer32 instead of INTEGER in SMIv2
 556:             UNITS       "Events"
 557:             MAX-ACCESS  read-only
 558:             STATUS      current
 559:             DESCRIPTION
 560:                     "The value of this object identifies the Network-
 561:                     side nN4 maximum status enquires received value
 562:                     for this UNI/NNI logical port.  If the logical
 563:                     port is not performing network-side procedures or
 564:                     is not performing LMI procedures, then this object
 565:                     is not instantiated.
 566: 
 567:                     This object applies only to LMI and always has a
 568:                     value of 5."
 569:             REFERENCE   "LMI [24]"
 570:             ::= { frMgtVCSigEntry 9 }
 571: 
 572:         frMgtVCSigNetnT3 OBJECT-TYPE
 573:             SYNTAX      INTEGER (5 | 10 | 15 | 20 | 25 | 30)
 573: warning - warning: use Integer32 instead of INTEGER in SMIv2
 574:             UNITS       "Seconds"
 575:             MAX-ACCESS  read-only
 576:             STATUS      current
 577:             DESCRIPTION
 578:                     "The value of this object identifies the Network-
 579:                     side nT3 timer (for nN4 status enquires received)
 580:                     value for this UNI/NNI logical port.  If the
 581:                     logical port is not performing network-side
 582:                     procedures or is not performing LMI procedures,
 583:                     then this object is not instantiated.
 584: 
 585:                       This object applies only to LMI."
 586:               REFERENCE   "LMI [24]"
 587:               DEFVAL { 20 }
 588:               ::= { frMgtVCSigEntry 10 }
...
 703: 
 704:         frMgtVCSigUserN391Admin OBJECT-TYPE
 705:             SYNTAX      INTEGER (1..255)
 705: warning - warning: use Integer32 instead of INTEGER in SMIv2
 706:             UNITS       "Polls"
 707:             MAX-ACCESS  read-write
 708:             STATUS      current
 709:             DESCRIPTION
 710:                     "The value of this object identifies the desired
 711:                     User-side N391 full status polling cycle value for
 712:                     this UNI/NNI logical port.  If the logical port is
 713:                     not performing user-side (bidirectional)
 714:                     procedures, then this object is not instantiated."
 715:             REFERENCE   "Q.933 Annex A [22],
 716:                          T1.617 Annex D [17]"
 717:             ::= { frMgtVCSigEntry 18 }
 718: 
 719:         frMgtVCSigUserN392Admin OBJECT-TYPE
 720:             SYNTAX      INTEGER (1..10)
 720: warning - warning: use Integer32 instead of INTEGER in SMIv2
 721:             UNITS       "Events"
 722:             MAX-ACCESS  read-write
 723:             STATUS      current
 724:             DESCRIPTION
 725:                     "The value of this object identifies the desired
 726:                     User-side N392 error threshold value for this
 727:                     UNI/NNI logical port.  If the logical port is not
 728:                     performing user-side (bidirectional) procedures,
 729:                     then this object is not instantiated."
 730:             REFERENCE   "Q.933 Annex A [22],
 731:                          T1.617 Annex D [17]"
 732:             ::= { frMgtVCSigEntry 19 }
 733: 
 734:         frMgtVCSigUserN393Admin OBJECT-TYPE
 735:             SYNTAX      INTEGER (1..10)
 735: warning - warning: use Integer32 instead of INTEGER in SMIv2
 736:             UNITS       "Events"
 737:             MAX-ACCESS  read-write
 738:             STATUS      current
 739:             DESCRIPTION
 740:                     "The value of this object identifies the desired
 741:                     User-side N393 monitored events count value for
 742:                     this UNI/NNI logical port.  If the logical port is
 743:                     not performing user-side (bidirectional)
 744:                     procedures, then this object is not instantiated."
 745:             REFERENCE   "Q.933 Annex A [22],
 746:                          T1.617 Annex D [17]"
 747:             ::= { frMgtVCSigEntry 20 }
 748: 
 749:         frMgtVCSigUserT391Admin OBJECT-TYPE
 750:             SYNTAX      INTEGER (5..30)
 750: warning - warning: use Integer32 instead of INTEGER in SMIv2
 751:             UNITS       "Seconds"
 752:             MAX-ACCESS  read-write
 753:             STATUS      current
 754:             DESCRIPTION
 755:                     "The value of this object identifies the desired
 756:                     User-side T391 link integrity verification polling
 757:                     timer value for this UNI/NNI logical port.  If the
 758:                     logical port is not performing user-side
 759:                     procedures, then this object is not instantiated."
 760:             REFERENCE   "Q.933 Annex A [22],
 761:                          T1.617 Annex D [17]"
 762:             ::= { frMgtVCSigEntry 21 }
 763: 
 764:         frMgtVCSigNetN392Admin OBJECT-TYPE
 765:             SYNTAX      INTEGER (1..10)
 765: warning - warning: use Integer32 instead of INTEGER in SMIv2
 766:             UNITS       "Events"
 767:             MAX-ACCESS  read-write
 768:             STATUS      current
 769:             DESCRIPTION
 770:                     "The value of this object identifies the desired
 771:                     Network-side N392 error threshold value (nN2 for
 772:                     LMI) for this UNI/NNI logical port.  If the
 773:                     logical port is not performing network-side
 774:                     procedures, then this object is not instantiated."
 775:             REFERENCE   "Q.933 Annex A [22],
 776:                          T1.617 Annex D [17],
 777:                          LMI [24]"
 778:             ::= { frMgtVCSigEntry 22 }
 779: 
 780:         frMgtVCSigNetN393Admin OBJECT-TYPE
 781:             SYNTAX      INTEGER (1..10)
 781: warning - warning: use Integer32 instead of INTEGER in SMIv2
 782:             UNITS       "Events"
 783:             MAX-ACCESS  read-write
 784:             STATUS      current
 785:             DESCRIPTION
 786:                     "The value of this object identifies the desired
 787:                     Network-side N393 monitored events count value
 788:                     (nN3 for LMI) for this UNI/NNI logical port.  If
 789:                     the logical port is not performing network-side
 790:                     procedures, then this object is not instantiated."
 791:             REFERENCE   "Q.933 Annex A [22],
 792:                          T1.617 Annex D [17],
 793:                          LMI [24]"
 794:             ::= { frMgtVCSigEntry 23 }
 795: 
 796:         frMgtVCSigNetT392Admin OBJECT-TYPE
 797:             SYNTAX      INTEGER (5..30)
 797: warning - warning: use Integer32 instead of INTEGER in SMIv2
 798:             UNITS       "Seconds"
 799:             MAX-ACCESS  read-write
 800:             STATUS      current
 801:             DESCRIPTION
 802:                     "The value of this object identifies the desired
 803:                     Network-side T392 polling verification timer value
 804:                     (nT2 for LMI)  for this UNI/NNI logical port. If
 805:                     the logical port is not performing network-side
 806:                     procedures, then this object is not instantiated."
 807:             REFERENCE   "Q.933 Annex A [22],
 808:                          T1.617 Annex D [17],
 809:                          LMI [24]"
 810:             ::= { frMgtVCSigEntry 24 }
 811: 
 812:         frMgtVCSigNetnT3Admin OBJECT-TYPE
 813:             SYNTAX      INTEGER (5 | 10 | 15 | 20 | 25 | 30)
 813: warning - warning: use Integer32 instead of INTEGER in SMIv2
 814:             UNITS       "Seconds"
 815:             MAX-ACCESS  read-write
 816:             STATUS      current
 817:             DESCRIPTION
 818:                     "The value of this object identifies the desired
 819:                     Network-side nT3 timer (for nN4 status enquires
 820:                     received) value for this UNI/NNI logical port. If
 821:                     the logical port is not performing network-side
 822:                     procedures or is not performing LMI procedures,
 823:                     then this object is not instantiated.  This object
 824:                     applies only to LMI."
 825:             REFERENCE   "LMI [24]"
 826:             ::= { frMgtVCSigEntry 25 }
 827: 
 828:         --
 829:         -- Frame Relay PVC End-points
 830:         --
...
1451: 
1452:         frPVCConnectIndexValue OBJECT-TYPE
1453:             SYNTAX      INTEGER (0..2147483647)
1453: warning - warning: use Integer32 instead of INTEGER in SMIv2
1454:             MAX-ACCESS  read-only
1455:             STATUS      current
1456:             DESCRIPTION
1457:                     "This object returns a hint to be used for
1458:                     frPVCConnectIndex when creating entries in the
1459:                     frPVCConnectTable.
1460: 
1461:                     The value 0 indicates that no unassigned entries
1462:                     are available.
1463: 
1464:                     To obtain the frPVCConnectIndex value for a new
1465:                     entry, the manager issues a management protocol
1466:                     retrieval operation to obtain the current value of
1467:                     this object.  After each retrieval, the agent must
1468:                     modify the value to the next unassigned index to
1469:                     prevent assignment of the same value to multiple
1470:                     management systems.
1471: 
1472:                     A management system should repeat the read to
1473:                     obtain a new value should an attempt to create the
1474:                     new row using the previously returned hint fail."
1475:             ::= { frnetservObjects 4 }
...
1957: 
1958:         frPVCConnectStatusChange  NOTIFICATION-TYPE
1958: warning - warning: notification `frPVCConnectStatusChange' is not reverse mappable
1958: minor error - object `frPVCConnectIndex' of notification `frPVCConnectStatusChange' must not be `not-accessible'

1958: minor error - object `frPVCConnectLowIfIndex' of notification `frPVCConnectStatusChange' must not be `not-accessible'

1958: minor error - object `frPVCConnectLowDLCIIndex' of notification `frPVCConnectStatusChange' must not be `not-accessible'

1958: minor error - object `frPVCConnectHighIfIndex' of notification `frPVCConnectStatusChange' must not be `not-accessible'

1958: minor error - object `frPVCConnectHighDLCIIndex' of notification `frPVCConnectStatusChange' must not be `not-accessible'
1959:             OBJECTS { frPVCConnectIndex,
1960:                       frPVCConnectLowIfIndex,
1961:                       frPVCConnectLowDLCIIndex,
1962:                       frPVCConnectHighIfIndex,
1963:                       frPVCConnectHighDLCIIndex,
1964:                       frPVCConnectL2hOperStatus,
1965:                       frPVCConnectH2lOperStatus,
1966:                       frPVCEndptRcvdSigStatus }
1967:             STATUS  deprecated
1968:             DESCRIPTION
1969:                     "Refer to the description of the
1970:                     frPVCConnectStatusNotif notification that has
1971:                     replaced this notification.  The notification is
1972:                     deprecated due to the incorrect inclusion of index
1973:                     values and to take advantage of the trap prefix
1974:                     for automatic conversion from SMIv2 to SMIv1 by
1975:                     making the one but last sub-ID a zero (i.e. the
1976:                     so-called trap prefix)."
1977:             ::= { frnetservTraps 1 }
...
2453: 
2454:         frnetservPVCNotifGroup NOTIFICATION-GROUP
2454: warning - warning: deprecated group `frnetservPVCNotifGroup' is not referenced in this module
2455:               NOTIFICATIONS { frPVCConnectStatusChange }
2456:               STATUS    deprecated
2457:               DESCRIPTION
2458:                     "Deprecated notification group.  The
2459:                     frPVCConnectStatusChange notification was flawed
2460:                     because it included redundant indexes and was not
2461:                     properly encoded for SMIv1 conversion."
2462:             ::= { frnetservGroups 12 }