smilint output for ./FRNETSERV-MIB
Message Severities |
Severity | Count |
minor error | 5 |
warning | 20 |
Message Types |
Type | Count |
group-unref (warning) | 1 |
integer-misuse (warning) | 18 |
notification-not-reversible (warning) | 1 |
notification-object-access (minor error) | 5 |
Messages:
FRNETSERV-MIB
1: -- extracted from rfc2954.txt
2: -- at Tue Oct 17 07:11:19 2000
436:
437: frMgtVCSigUserN391 OBJECT-TYPE
438: SYNTAX INTEGER (1..255)
438: warning -
warning: use Integer32 instead of INTEGER in SMIv2
439: UNITS "Polls"
440: MAX-ACCESS read-only
441: STATUS current
442: DESCRIPTION
443: "The value of this object identifies the User-side
444: N391 full status polling cycle value for this
445: UNI/NNI logical port. If the logical port is not
446: performing user-side (bidirectional) procedures,
447: then this object is not instantiated and an
448: attempt to read will result in the noSuchInstance
449: exception response."
450: REFERENCE "Q.933 Annex A [22],
451: T1.617 Annex D [17]"
452: DEFVAL { 6 }
453: ::= { frMgtVCSigEntry 2 }
454:
455: frMgtVCSigUserN392 OBJECT-TYPE
456: SYNTAX INTEGER (1..10)
456: warning -
warning: use Integer32 instead of INTEGER in SMIv2
457: UNITS "Events"
458: MAX-ACCESS read-only
459: STATUS current
460: DESCRIPTION
461: "The value of this object identifies the User-side
462: N392 error threshold value for this UNI/NNI
463: logical port. If the logical port is not
464: performing user-side (bidirectional) procedures,
465: then this object is not instantiated."
466: REFERENCE "Q.933 Annex A [22],
467: T1.617 Annex D [17]"
468: DEFVAL { 3 }
469: ::= { frMgtVCSigEntry 3 }
470:
471: frMgtVCSigUserN393 OBJECT-TYPE
472: SYNTAX INTEGER (1..10)
472: warning -
warning: use Integer32 instead of INTEGER in SMIv2
473: UNITS "Events"
474: MAX-ACCESS read-only
475: STATUS current
476: DESCRIPTION
477: "The value of this object identifies the User-side
478: N393 monitored events count value for this UNI/NNI
479: logical port. If the logical port is not
480: performing user-side (bidirectional) procedures,
481: then this object is not instantiated."
482: REFERENCE "Q.933 Annex A [22],
483: T1.617 Annex D [17]"
484: DEFVAL { 4 }
485: ::= { frMgtVCSigEntry 4 }
486:
487: frMgtVCSigUserT391 OBJECT-TYPE
488: SYNTAX INTEGER (5..30)
488: warning -
warning: use Integer32 instead of INTEGER in SMIv2
489: UNITS "Seconds"
490: MAX-ACCESS read-only
491: STATUS current
492: DESCRIPTION
493: "The value of this object identifies the User-side
494: T391 link integrity verification polling timer
495: value for this UNI/NNI logical port. If the
496: logical port is not performing user-side
497: procedures, then this object is not instantiated."
498: REFERENCE "Q.933 Annex A [22],
499: T1.617 Annex D [17]"
500: DEFVAL { 10 }
501: ::= { frMgtVCSigEntry 5 }
502:
503: frMgtVCSigNetN392 OBJECT-TYPE
504: SYNTAX INTEGER (1..10)
504: warning -
warning: use Integer32 instead of INTEGER in SMIv2
505: UNITS "Events"
506: MAX-ACCESS read-only
507: STATUS current
508: DESCRIPTION
509: "The value of this object identifies the Network-
510: side N392 error threshold value (nN2 for LMI) for
511: this UNI/NNI logical port. If the logical port is
512: not performing network-side procedures, then this
513: object is not instantiated."
514: REFERENCE "Q.933 Annex A [22],
515: T1.617 Annex D [17],
516: LMI [24]"
517: DEFVAL { 3 }
518: ::= { frMgtVCSigEntry 6 }
519:
520: frMgtVCSigNetN393 OBJECT-TYPE
521: SYNTAX INTEGER (1..10)
521: warning -
warning: use Integer32 instead of INTEGER in SMIv2
522: UNITS "Events"
523: MAX-ACCESS read-only
524: STATUS current
525: DESCRIPTION
526: "The value of this object identifies the Network-
527: side N393 monitored events count value (nN3 for
528: LMI) for this UNI/NNI logical port. If the
529: logical port is not performing network-side
530: procedures, then this object is not instantiated."
531: REFERENCE "Q.933 Annex A [22],
532: T1.617 Annex D [17],
533: LMI [24]"
534: DEFVAL { 4 }
535: ::= { frMgtVCSigEntry 7 }
536:
537: frMgtVCSigNetT392 OBJECT-TYPE
538: SYNTAX INTEGER (5..30)
538: warning -
warning: use Integer32 instead of INTEGER in SMIv2
539: UNITS "Seconds"
540: MAX-ACCESS read-only
541: STATUS current
542: DESCRIPTION
543: "The value of this object identifies the Network-
544: side T392 polling verification timer value (nT2
545: for LMI) for this UNI/NNI logical port. If the
546: logical port is not performing network-side
547: procedures, then this object is not instantiated."
548: REFERENCE "Q.933 Annex A [22],
549: T1.617 Annex D [17],
550: LMI [24]"
551: DEFVAL { 15 }
552: ::= { frMgtVCSigEntry 8 }
553:
554: frMgtVCSigNetnN4 OBJECT-TYPE
555: SYNTAX INTEGER (5..5)
555: warning -
warning: use Integer32 instead of INTEGER in SMIv2
556: UNITS "Events"
557: MAX-ACCESS read-only
558: STATUS current
559: DESCRIPTION
560: "The value of this object identifies the Network-
561: side nN4 maximum status enquires received value
562: for this UNI/NNI logical port. If the logical
563: port is not performing network-side procedures or
564: is not performing LMI procedures, then this object
565: is not instantiated.
566:
567: This object applies only to LMI and always has a
568: value of 5."
569: REFERENCE "LMI [24]"
570: ::= { frMgtVCSigEntry 9 }
571:
572: frMgtVCSigNetnT3 OBJECT-TYPE
573: SYNTAX INTEGER (5 | 10 | 15 | 20 | 25 | 30)
573: warning -
warning: use Integer32 instead of INTEGER in SMIv2
574: UNITS "Seconds"
575: MAX-ACCESS read-only
576: STATUS current
577: DESCRIPTION
578: "The value of this object identifies the Network-
579: side nT3 timer (for nN4 status enquires received)
580: value for this UNI/NNI logical port. If the
581: logical port is not performing network-side
582: procedures or is not performing LMI procedures,
583: then this object is not instantiated.
584:
585: This object applies only to LMI."
586: REFERENCE "LMI [24]"
587: DEFVAL { 20 }
588: ::= { frMgtVCSigEntry 10 }
...
703:
704: frMgtVCSigUserN391Admin OBJECT-TYPE
705: SYNTAX INTEGER (1..255)
705: warning -
warning: use Integer32 instead of INTEGER in SMIv2
706: UNITS "Polls"
707: MAX-ACCESS read-write
708: STATUS current
709: DESCRIPTION
710: "The value of this object identifies the desired
711: User-side N391 full status polling cycle value for
712: this UNI/NNI logical port. If the logical port is
713: not performing user-side (bidirectional)
714: procedures, then this object is not instantiated."
715: REFERENCE "Q.933 Annex A [22],
716: T1.617 Annex D [17]"
717: ::= { frMgtVCSigEntry 18 }
718:
719: frMgtVCSigUserN392Admin OBJECT-TYPE
720: SYNTAX INTEGER (1..10)
720: warning -
warning: use Integer32 instead of INTEGER in SMIv2
721: UNITS "Events"
722: MAX-ACCESS read-write
723: STATUS current
724: DESCRIPTION
725: "The value of this object identifies the desired
726: User-side N392 error threshold value for this
727: UNI/NNI logical port. If the logical port is not
728: performing user-side (bidirectional) procedures,
729: then this object is not instantiated."
730: REFERENCE "Q.933 Annex A [22],
731: T1.617 Annex D [17]"
732: ::= { frMgtVCSigEntry 19 }
733:
734: frMgtVCSigUserN393Admin OBJECT-TYPE
735: SYNTAX INTEGER (1..10)
735: warning -
warning: use Integer32 instead of INTEGER in SMIv2
736: UNITS "Events"
737: MAX-ACCESS read-write
738: STATUS current
739: DESCRIPTION
740: "The value of this object identifies the desired
741: User-side N393 monitored events count value for
742: this UNI/NNI logical port. If the logical port is
743: not performing user-side (bidirectional)
744: procedures, then this object is not instantiated."
745: REFERENCE "Q.933 Annex A [22],
746: T1.617 Annex D [17]"
747: ::= { frMgtVCSigEntry 20 }
748:
749: frMgtVCSigUserT391Admin OBJECT-TYPE
750: SYNTAX INTEGER (5..30)
750: warning -
warning: use Integer32 instead of INTEGER in SMIv2
751: UNITS "Seconds"
752: MAX-ACCESS read-write
753: STATUS current
754: DESCRIPTION
755: "The value of this object identifies the desired
756: User-side T391 link integrity verification polling
757: timer value for this UNI/NNI logical port. If the
758: logical port is not performing user-side
759: procedures, then this object is not instantiated."
760: REFERENCE "Q.933 Annex A [22],
761: T1.617 Annex D [17]"
762: ::= { frMgtVCSigEntry 21 }
763:
764: frMgtVCSigNetN392Admin OBJECT-TYPE
765: SYNTAX INTEGER (1..10)
765: warning -
warning: use Integer32 instead of INTEGER in SMIv2
766: UNITS "Events"
767: MAX-ACCESS read-write
768: STATUS current
769: DESCRIPTION
770: "The value of this object identifies the desired
771: Network-side N392 error threshold value (nN2 for
772: LMI) for this UNI/NNI logical port. If the
773: logical port is not performing network-side
774: procedures, then this object is not instantiated."
775: REFERENCE "Q.933 Annex A [22],
776: T1.617 Annex D [17],
777: LMI [24]"
778: ::= { frMgtVCSigEntry 22 }
779:
780: frMgtVCSigNetN393Admin OBJECT-TYPE
781: SYNTAX INTEGER (1..10)
781: warning -
warning: use Integer32 instead of INTEGER in SMIv2
782: UNITS "Events"
783: MAX-ACCESS read-write
784: STATUS current
785: DESCRIPTION
786: "The value of this object identifies the desired
787: Network-side N393 monitored events count value
788: (nN3 for LMI) for this UNI/NNI logical port. If
789: the logical port is not performing network-side
790: procedures, then this object is not instantiated."
791: REFERENCE "Q.933 Annex A [22],
792: T1.617 Annex D [17],
793: LMI [24]"
794: ::= { frMgtVCSigEntry 23 }
795:
796: frMgtVCSigNetT392Admin OBJECT-TYPE
797: SYNTAX INTEGER (5..30)
797: warning -
warning: use Integer32 instead of INTEGER in SMIv2
798: UNITS "Seconds"
799: MAX-ACCESS read-write
800: STATUS current
801: DESCRIPTION
802: "The value of this object identifies the desired
803: Network-side T392 polling verification timer value
804: (nT2 for LMI) for this UNI/NNI logical port. If
805: the logical port is not performing network-side
806: procedures, then this object is not instantiated."
807: REFERENCE "Q.933 Annex A [22],
808: T1.617 Annex D [17],
809: LMI [24]"
810: ::= { frMgtVCSigEntry 24 }
811:
812: frMgtVCSigNetnT3Admin OBJECT-TYPE
813: SYNTAX INTEGER (5 | 10 | 15 | 20 | 25 | 30)
813: warning -
warning: use Integer32 instead of INTEGER in SMIv2
814: UNITS "Seconds"
815: MAX-ACCESS read-write
816: STATUS current
817: DESCRIPTION
818: "The value of this object identifies the desired
819: Network-side nT3 timer (for nN4 status enquires
820: received) value for this UNI/NNI logical port. If
821: the logical port is not performing network-side
822: procedures or is not performing LMI procedures,
823: then this object is not instantiated. This object
824: applies only to LMI."
825: REFERENCE "LMI [24]"
826: ::= { frMgtVCSigEntry 25 }
827:
828: --
829: -- Frame Relay PVC End-points
830: --
...
1451:
1452: frPVCConnectIndexValue OBJECT-TYPE
1453: SYNTAX INTEGER (0..2147483647)
1453: warning -
warning: use Integer32 instead of INTEGER in SMIv2
1454: MAX-ACCESS read-only
1455: STATUS current
1456: DESCRIPTION
1457: "This object returns a hint to be used for
1458: frPVCConnectIndex when creating entries in the
1459: frPVCConnectTable.
1460:
1461: The value 0 indicates that no unassigned entries
1462: are available.
1463:
1464: To obtain the frPVCConnectIndex value for a new
1465: entry, the manager issues a management protocol
1466: retrieval operation to obtain the current value of
1467: this object. After each retrieval, the agent must
1468: modify the value to the next unassigned index to
1469: prevent assignment of the same value to multiple
1470: management systems.
1471:
1472: A management system should repeat the read to
1473: obtain a new value should an attempt to create the
1474: new row using the previously returned hint fail."
1475: ::= { frnetservObjects 4 }
...
1957:
1958: frPVCConnectStatusChange NOTIFICATION-TYPE
1958: warning -
warning: notification `frPVCConnectStatusChange' is not reverse mappable
1958: minor error -
object `frPVCConnectIndex' of notification `frPVCConnectStatusChange' must not be `not-accessible'
1958: minor error -
object `frPVCConnectLowIfIndex' of notification `frPVCConnectStatusChange' must not be `not-accessible'
1958: minor error -
object `frPVCConnectLowDLCIIndex' of notification `frPVCConnectStatusChange' must not be `not-accessible'
1958: minor error -
object `frPVCConnectHighIfIndex' of notification `frPVCConnectStatusChange' must not be `not-accessible'
1958: minor error -
object `frPVCConnectHighDLCIIndex' of notification `frPVCConnectStatusChange' must not be `not-accessible'
1959: OBJECTS { frPVCConnectIndex,
1960: frPVCConnectLowIfIndex,
1961: frPVCConnectLowDLCIIndex,
1962: frPVCConnectHighIfIndex,
1963: frPVCConnectHighDLCIIndex,
1964: frPVCConnectL2hOperStatus,
1965: frPVCConnectH2lOperStatus,
1966: frPVCEndptRcvdSigStatus }
1967: STATUS deprecated
1968: DESCRIPTION
1969: "Refer to the description of the
1970: frPVCConnectStatusNotif notification that has
1971: replaced this notification. The notification is
1972: deprecated due to the incorrect inclusion of index
1973: values and to take advantage of the trap prefix
1974: for automatic conversion from SMIv2 to SMIv1 by
1975: making the one but last sub-ID a zero (i.e. the
1976: so-called trap prefix)."
1977: ::= { frnetservTraps 1 }
...
2453:
2454: frnetservPVCNotifGroup NOTIFICATION-GROUP
2454: warning -
warning: deprecated group `frnetservPVCNotifGroup' is not referenced in this module
2455: NOTIFICATIONS { frPVCConnectStatusChange }
2456: STATUS deprecated
2457: DESCRIPTION
2458: "Deprecated notification group. The
2459: frPVCConnectStatusChange notification was flawed
2460: because it included redundant indexes and was not
2461: properly encoded for SMIv1 conversion."
2462: ::= { frnetservGroups 12 }