smilint output for ./ATM-ACCOUNTING-INFORMATION-MIB


Message Severities
SeverityCount
minor error1
change recommended4
warning12
Message Types
TypeCount
access-counter-illegal (change recommended)4
integer-misuse (warning)12
revision-missing (minor error)1

Messages:

ATM-ACCOUNTING-INFORMATION-MIB

   1: -- extracted from rfc2512.txt
   2: -- at Mon Nov 15 17:11:39 1999
  12: 
  13: atmAccountingInformationMIB MODULE-IDENTITY
  14:     LAST-UPDATED "9611052000Z"
  15:     ORGANIZATION "IETF AToM MIB Working Group"
  16:     CONTACT-INFO "
  17:                   Keith McCloghrie
  18:                   Cisco Systems, Inc.
  19:                   170 West Tasman Drive,
  20:                   San Jose CA 95134-1706.
  21:                   Phone: +1 408 526 5260
  22:                   Email: kzm@cisco.com"
  23: 
  24:     DESCRIPTION
  25:             "The MIB module for identifying items of accounting
  26:             information which are applicable to ATM connections."
  27:     ::= { mib-2 59 }
  27: minor error - revision for last update is missing
  28: 
...
 102: 
 103: atmAcctngVpi OBJECT-TYPE
 104:     SYNTAX      INTEGER (0..4095)
 104: warning - warning: use Integer32 instead of INTEGER in SMIv2
 105:     MAX-ACCESS  not-accessible
 106:     STATUS      current
 107:     DESCRIPTION
 108:             "The VPI used for the connection."
 109:     ::= { atmAcctngDataObjects 5 }
 110: 
 111: atmAcctngVci OBJECT-TYPE
 112:     SYNTAX      INTEGER (0..65535)
 112: warning - warning: use Integer32 instead of INTEGER in SMIv2
 113:     MAX-ACCESS  not-accessible
 114:     STATUS      current
 115:     DESCRIPTION
 116:             "The VCI used for the connection."
 117:     ::= { atmAcctngDataObjects 6 }
...
 194: 
 195: atmAcctngTransmittedCells OBJECT-TYPE
 195: change recommended - warning: counter object `atmAcctngTransmittedCells' must be `read-only' or `accessible-for-notify'
 196:     SYNTAX      Counter64
 197:     MAX-ACCESS  not-accessible
 198:     STATUS      current
 199:     DESCRIPTION
 200:             "The number of cells, including OAM cells, transmitted by
 201:             this switch on this connection."
 202:     ::= { atmAcctngDataObjects 15 }
 203: 
 204: atmAcctngTransmittedClp0Cells OBJECT-TYPE
 204: change recommended - warning: counter object `atmAcctngTransmittedClp0Cells' must be `read-only' or `accessible-for-notify'
 205:     SYNTAX      Counter64
 206:     MAX-ACCESS  not-accessible
 207:     STATUS      current
 208:     DESCRIPTION
 209:             "The number of cells with CLP=0, including OAM cells,
 210:             transmitted by this switch on this connection."
 211:     ::= { atmAcctngDataObjects 16 }
 212: 
 213: atmAcctngReceivedCells OBJECT-TYPE
 213: change recommended - warning: counter object `atmAcctngReceivedCells' must be `read-only' or `accessible-for-notify'
 214:     SYNTAX      Counter64
 215:     MAX-ACCESS  not-accessible
 216:     STATUS      current
 217:     DESCRIPTION
 218:             "The number of cells, including OAM cells, received by this
 219:             switch on this connection."
 220:     ::= { atmAcctngDataObjects 17 }
 221: 
 222: atmAcctngReceivedClp0Cells OBJECT-TYPE
 222: change recommended - warning: counter object `atmAcctngReceivedClp0Cells' must be `read-only' or `accessible-for-notify'
 223:     SYNTAX      Counter64
 224:     MAX-ACCESS  not-accessible
 225:     STATUS      current
 226:     DESCRIPTION
 227:             "The number of cells with CLP=0, including OAM cells,
 228:             received by this switch on this connection."
 229:     ::= { atmAcctngDataObjects 18 }
...
 243: 
 244: atmAcctngTransmitTrafficDescriptorParam1 OBJECT-TYPE
 245:     SYNTAX      INTEGER (0..2147483647)
 245: warning - warning: use Integer32 instead of INTEGER in SMIv2
 246:     MAX-ACCESS  not-accessible
 247:     STATUS      current
 248:     DESCRIPTION
 249:             "The first traffic descriptor parameter in the direction in
 250:             which this switch transmits cells on this connection.
 251:             Interpretation of this parameter is dependent on the value
 252:             of atmAcctngTransmitTrafficDescriptorType."
 253:     ::= { atmAcctngDataObjects 20 }
 254: 
 255: atmAcctngTransmitTrafficDescriptorParam2 OBJECT-TYPE
 256:     SYNTAX      INTEGER (0..2147483647)
 256: warning - warning: use Integer32 instead of INTEGER in SMIv2
 257:     MAX-ACCESS  not-accessible
 258:     STATUS      current
 259:     DESCRIPTION
 260:             "The second traffic descriptor parameter in the direction in
 261:             which this switch transmits cells on this connection.
 262:             Interpretation of this parameter is dependent on the value
 263:             of atmAcctngTransmitTrafficDescriptorType."
 264:     ::= { atmAcctngDataObjects 21 }
 265: 
 266: atmAcctngTransmitTrafficDescriptorParam3 OBJECT-TYPE
 267:     SYNTAX      INTEGER (0..2147483647)
 267: warning - warning: use Integer32 instead of INTEGER in SMIv2
 268:     MAX-ACCESS  not-accessible
 269:     STATUS      current
 270:     DESCRIPTION
 271:             "The third traffic descriptor parameter in the direction in
 272:             which this switch transmits cells on this connection.
 273:             Interpretation of this parameter is dependent on the value
 274:             of atmAcctngTransmitTrafficDescriptorType."
 275:     ::= { atmAcctngDataObjects 22 }
 276: 
 277: atmAcctngTransmitTrafficDescriptorParam4 OBJECT-TYPE
 278:     SYNTAX      INTEGER (0..2147483647)
 278: warning - warning: use Integer32 instead of INTEGER in SMIv2
 279:     MAX-ACCESS  not-accessible
 280:     STATUS      current
 281:     DESCRIPTION
 282:             "The fourth traffic descriptor parameter in the direction in
 283:             which this switch transmits cells on this connection.
 284:             Interpretation of this parameter is dependent on the value
 285:             of atmAcctngTransmitTrafficDescriptorType."
 286:     ::= { atmAcctngDataObjects 23 }
 287: 
 288: atmAcctngTransmitTrafficDescriptorParam5 OBJECT-TYPE
 289:     SYNTAX      INTEGER (0..2147483647)
 289: warning - warning: use Integer32 instead of INTEGER in SMIv2
 290:     MAX-ACCESS  not-accessible
 291:     STATUS      current
 292:     DESCRIPTION
 293:             "The fifth traffic descriptor parameter in the direction in
 294:             which this switch transmits cells on this connection.
 295:             Interpretation of this parameter is dependent on the value
 296:             of atmAcctngTransmitTrafficDescriptorType."
 297:     ::= { atmAcctngDataObjects 24 }
...
 311: 
 312: atmAcctngReceiveTrafficDescriptorParam1 OBJECT-TYPE
 313:     SYNTAX      INTEGER (0..2147483647)
 313: warning - warning: use Integer32 instead of INTEGER in SMIv2
 314:     MAX-ACCESS  not-accessible
 315:     STATUS      current
 316:     DESCRIPTION
 317:             "The first traffic descriptor parameter in the direction in
 318:             which this switch receives cells on this connection.
 319:             Interpretation of this parameter is dependent on the value
 320:             of atmAcctngReceiveTrafficDescriptorType."
 321:     ::= { atmAcctngDataObjects 26 }
 322: 
 323: atmAcctngReceiveTrafficDescriptorParam2 OBJECT-TYPE
 324:     SYNTAX      INTEGER (0..2147483647)
 324: warning - warning: use Integer32 instead of INTEGER in SMIv2
 325:     MAX-ACCESS  not-accessible
 326:     STATUS      current
 327:     DESCRIPTION
 328:             "The second traffic descriptor parameter in the direction in
 329:             which this switch receives cells on this connection.
 330:             Interpretation of this parameter is dependent on the value
 331:             of atmAcctngReceiveTrafficDescriptorType."
 332:     ::= { atmAcctngDataObjects 27 }
 333: 
 334: atmAcctngReceiveTrafficDescriptorParam3 OBJECT-TYPE
 335:     SYNTAX      INTEGER (0..2147483647)
 335: warning - warning: use Integer32 instead of INTEGER in SMIv2
 336:     MAX-ACCESS  not-accessible
 337:     STATUS      current
 338:     DESCRIPTION
 339:             "The third traffic descriptor parameter in the direction in
 340:             which this switch receives cells on this connection.
 341:             Interpretation of this parameter is dependent on the value
 342:             of atmAcctngReceiveTrafficDescriptorType."
 343:     ::= { atmAcctngDataObjects 28 }
 344: 
 345: atmAcctngReceiveTrafficDescriptorParam4 OBJECT-TYPE
 346:     SYNTAX      INTEGER (0..2147483647)
 346: warning - warning: use Integer32 instead of INTEGER in SMIv2
 347:     MAX-ACCESS  not-accessible
 348:     STATUS      current
 349:     DESCRIPTION
 350:             "The fourth traffic descriptor parameter in the direction in
 351:             which this switch receives cells on this connection.
 352:             Interpretation of this parameter is dependent on the value
 353:             of atmAcctngReceiveTrafficDescriptorType."
 354:     ::= { atmAcctngDataObjects 29 }
 355: 
 356: atmAcctngReceiveTrafficDescriptorParam5 OBJECT-TYPE
 357:     SYNTAX      INTEGER (0..2147483647)
 357: warning - warning: use Integer32 instead of INTEGER in SMIv2
 358:     MAX-ACCESS  not-accessible
 359:     STATUS      current
 360:     DESCRIPTION
 361:             "The fifth traffic descriptor parameter in the direction in
 362:             which this switch receives cells on this connection.
 363:             Interpretation of this parameter is dependent on the value
 364:             of atmAcctngReceiveTrafficDescriptorType."
 365:     ::= { atmAcctngDataObjects 30 }